POST /smart-transfer-of-reads/v1/{mpid}/comparison-requests/{comparison_request_id}/reject
Rejects a comparison.
Request
Method and path:
POST /smart-transfer-of-reads/v1/{mpid}/comparison-requests/{comparison_request_id}/reject
Headers:
X-API-KEYorAuthorization: Bearer <token>(one required). API key takes precedence when both are supplied.X-IDEMPOTENCY-KEY(required): non-empty string.
Path parameters:
mpid(required): string supplier MPID.comparison_request_id(required): UUID comparison ID.
Body schema:
SmartRejectComparisonRequestorSmartRejectEstimateComparisonRequest, depending on comparison version.
Initial/dispute rejection supplies one cumulative counter-reading for every transfer-date Smart meter:
{
"additional_information": "Counterproposal following supplier review",
"meters": [
{
"meter_id": "A123456789",
"registers": [
{
"register_id": "C",
"disputed_reading_value": "12345.6",
"proposed_reading_value": "12350.0",
"reading_datetime": "2026-10-12T00:00:00Z",
"reading_method": "A",
"proposed_reading_type": "A",
"d0300_proposed_reading_status": "P"
}
]
}
]
}
SSI queues D0300 and awaits the counterparty. Subsequent received proposals have their own comparison IDs.
For MANUAL_SMART_LOSS_ESTIMATE, supply a complete replacement reading set:
{
"bsc_validation": "U",
"meters": [
{
"meter_id": "A123456789",
"reading_type": "A",
"meter_reading_flag": true,
"reading_datetime": "2026-10-12T00:00:00Z",
"reading_method": "A",
"cumulative_register_reading": "12350.678"
}
]
}
Estimate replacement queues D0010 and awaits the dispute period. For MANUAL_SMART_COA, send {}: rejection fails the process for manual resolution and sends no D0300.
Response
Success:
202 Accepted- Body type:
SmartComparisonDecisionResponse, withstatus: "REJECTED". - CoA rejection includes
additional_information: "The readings require manual resolution. No D0300 was sent."; other variants return null.
Other documented responses:
401/403Authentication or supplier-access failure.404Supplier, owned comparison/process or required source evidence not found.422Invalid body/path, unavailable comparison/process state, mismatched rejection variant, or invalid coverage/proposal/source evidence.428MissingX-IDEMPOTENCY-KEY.
Field-level constraints: